The VIG-LPC-EN is a Gent made additional Loop Card which is designed for and works on Gent Vigilon Panels. The new Loop Card is designed to be able to fully comply with the already existing EN panel, and is available also on versions of the Vigilon range such as EN The increased power allows for up to EN sensor-sounder-strobes on a 2km loop, meaning the loop card can manage up. Gent 4 zone fire alarm manual. I have installed a new 4 zone gent xenex fire alarm panel. zone 14 zone 3 zone 7 zone 11 zone 15 zone 4 zone 8 zone 12 zone 16 disablement zone 1 zone 5 zone 9 zone 13 system fault sound alarms silence alarms power fault reset cancel buzzer sounder disablement / 01/ 10 nano fire alarm system gent by honeywell menu power [ green led] fire [ red led] fault. Vigilon Fire System GENT Designed to EN54 Pt 2 4 Panel Healthy Active Fault/Dis Fire Routing O/P EN Vigilon 4-loop panel Network Node or BS Vigilon 4-loop panel On BS Vigilon panel labelled as: Commission Warning * NOT applicable for Network Node # NOT USED on BS Vigilon panel # # # *File Size: 1MB.
manual is a guide to be read in conjunction with the recommendations in BSPart , which is the code of practice for Fire detection and alarm system for buildings. Associated Documents 34K-MAN-OPS-V3+ Operating Manual for Vigilon V3+ System GENT Supervisor Operator's Manual (for V3+ system only) Conventions. Voids in the same fire compartment should be included in the same floor zone. The maximum floor area of a zone should not be greater than 2,m2, except for some large open plan areas that incorporate manual call points only, which can be extended to 10,m2. The maximum search distance for the fire fighters to see the seat of the. the need for manual intervention by fire fighters. The standard Vigilon Panel has 24 hour battery standby and up to 4 loops and a network card. The enhanced panel can offer 6 loops and a network card and up to 72 hour battery standby. Fire plans can be tailored to precisely meet project requirements. Vigilon Control Panel A B C dimensions (mm).
GENT Xenex range of 1,2,4 and 8 zone fire Control and Repeat panels These instructions must be left on site with the person responsible for the fire alarm system. This publication covers the: GENT range XEN1, XEN2, XEN4 and XEN8 fire alarm control panels. GENT XEN RPT fire alarm repeat panel. Design and installation Specifications 2 System design 5 Cables 8. View and Download Honeywell GENT operating instructions manual online. And Vigilon panel and Network node Fire detection. GENT security system pdf manual download. The panel controls are password protected and must only be operated by the person responsible for the fire system. Control panel The control panel is the heart of the system. It is normally located near to the main entry or exit point of the protected premises. The control panel continuously monitor devices that are connected to the device loop.
0コメント