World leaders of innovative solutions in fire detection and alarm systems. Ampac Pty Limited specialises in the design, manufacturing and technical support for a complete range of system solutions. We supply systems for a vast variety of applications including commercial and industrial buildings, mines, prisons, hospitals, hotels, and multi. Press the alarm test switch until alarm LED illuminates. Buzzer also operates. Relays RL1 and RL2 operates on API Measure for 24 VDC on bell output voltage TB1 terminals 7 8. Measure for 0V on door holder output TB1 9 10 ISOLATE (AZF) With the AZF in alarm, select the isolate position. The isolate indicator will illuminate. AllFile Size: 28KB. FireFinder Technical Manual ConfigManager FireFinder Detector Manual Australian Standards: AS - Maintenance of Fire Protection Systems and equipment - Fire Detection and Alarm Systems. AS - Fire Detection, Warning, Control and Intercom Systems – Control and Indicating Equipment. Part 1 and Part 5 Symbols.
nzs fire alarm systems in buildings. as/nzs electromagnetic interference. ampac technologies pty ltd unit d, 33 porana road glenfield auckland new zealand ph: fax: note: information contained in this document is subject to change without notice. uncontrolled document nz automatic fire alarm. FireFinder is a multi microprocessor controlled Intelligent Fire Alarm Control Panel. Modular in design, the FireFinder provides flexibility and versatility that can be configured to operate with both intelligent analogue addressable and conventional devices in the one system. Available in single or multiple loop configurations, the FireFinder. Ampac LoopSense 1 Loop 32 Zone Metal Fire Alarm Control Panel - LoopSense is an Intelligent Analogue Addressable Fire Alarm Control Panel. Available in one or two loops, the LoopSense comes packed with options and features that facilitate flexibility, ease of installation and commissioning.
1 Fire Brigade Responding To Alarm 1. Indicators-Alarm Indicator Flashing.-Location of Alarm on LCD Display.-First Alarm Displayed. 2. Isolate External Bell Isolate Warning System Press Press 3. Acknowledge Alarm Press 4. Isolate Alarm Press 5. If multiple alarms exist repeat 3 and 4 for second alarm and so on. 6. To Reset Panel Press WARNING SYS ISOLATE. Output to fire alarm devices Output to fire alarm routing equipment Input from fire alarm routing equipment Output type A to fire protection equipment Delays to outputs – configuration of delays (for item C) Delays to outputs – control of delays (for item C). disable alarms lcd display of description type, address, date time and number of disables 3) sounder silence fire led steady if necessary press to silence sounders indicator will turn on 3) reset alarms press to reset all alarms description date time loop no sensor no status: alarm sensor alarms 1 of xx type loop no sensor no status: dis.
0コメント